Its main purpose is to distribute the pressure applied by the pole’s upper disc evenly across a much larger ceiling surface, reducing the point load on delicate plasterboard or drywall ceilings and significantly improving safety and structural integrity.
Key Features
Force Distribution
- Expands the contact area between the pole and the ceiling by 5.5 times, reducing concentrated stress and minimising the risk of ceiling damage.
Material
- Circular pressed laminated board
- Diameter: 470 mm
- Lightweight yet strong construction ensures durability without adding unnecessary ceiling load.
Design
- Finished in black for a sleek, discreet appearance.
- Features an engraved area precisely shaped to hold the Lupit Pole Classic upper disc securely in place while still allowing the pole to be easily installed and removed without dismounting the plate itself.
Mounting System
- Attached to the ceiling using 4 screws (standard “single plaster” screws provided).
- Note: Due to the wide variety of plaster ceiling constructions, users must verify that the provided screws are suitable for their specific ceiling type. In some cases, additional or alternative mounting hardware may be required for safe installation.
Easy Installation
- Simple, fast mounting process designed for home users.
- Once installed, the plate stays securely fixed to the ceiling, ready to accommodate the pole setup repeatedly without additional adjustments.
Applications
- Ideal for home pole fitness setups where plasterboard ceilings are present.
- Provides peace of mind by ensuring the ceiling can safely handle the compression forces from pole use.
- Allows frequent installation/removal of the Lupit Pole Classic without repeated ceiling stress.
Compatibility
Important:
This accessory is only compatible with Lupit Pole Classic – Home Edition poles. It is not designed for other Lupit pole models or third-party poles.
Summary
The Lupit Plaster Ceiling Upper Plate is an essential accessory for pole enthusiasts using Lupit Pole Classic at home, particularly when mounting under plasterboard ceilings. By intelligently distributing forces over a much larger area, it enhances safety, protects ceiling integrity, and supports a professional, reliable pole fitness experience at home.
Installation Instructions for Lupit Plaster Ceiling Upper Plate
Using M6 x 65 mm Metal Hollow Wall Anchors (for use with the Lupit Plaster Ceiling Upper Plate)
Verify Compatibility:
- Ensure the ceiling is a false ceiling made of plasterboard (14–32 mm thick). These anchors are designed for cavity wall materials only and are not suitable for solid materials
- concrete, brick, or wood.
Tools Required:
- Drill with a 13 mm drill bit
- Screwdriver or Hollow Wall Anchor Setting Tool
- Measuring tape & pencil
- Vacuum or brush (to clean holes)
- Lupit Plaster Ceiling Upper Plate (for marking)
Use the Lupit Plaster Ceiling Upper Plate as a Template:
Hold the plate in the desired position on the false ceiling. Make sure it is level and aligned.
Mark the Drill Holes:
Use a pencil to mark the anchor positions through the mounting holes of the plate.
Drill Carefully:
Using a 13 mm drill bit, drill perpendicular to the surface at the marked points.
to Ensure the depth is sufficient to accommodate the anchor.
Clean Out Dust:
Use a vacuum or brush to remove any plaster dust from the holes to ensure better grip.
Insert the Anchor Body:
Push or gently tap each anchor into its hole until the collar is flush with the ceiling surface.
Set the Anchor:
- Insert the M6 screw into the anchor and begin tightening with a screwdriver or setting tool.
- As the screw is turned, the anchor will expand behind the plasterboard, locking it securely in place.
- Do not overtighten. Stop once firm resistance is felt.
Attach the Plate:
Align the Lupit Plaster Ceiling Upper Plate with the installed anchors and fasten it using the supplied M6 screws.
Check the Stability:
Ensure that all fixings are tight and that the plate is securely fastened without
wobbling or movement.
- The Lupit Plaster Ceiling Upper Plate must only be mounted on a false ceiling
- made of standard plasterboard (12.5 mm or thicker) supported by a properly built substructure.
- Load capacity depends on the quality and condition of the ceiling.
- Lupit Pole d.o.o. accepts no responsibility for improper installation, use on
- unsuitable surfaces, or overloading.
- The entire responsibility lies with the person or professional installing the
- product. If in doubt, consult a qualified installer or structural engineer.
These metal hollow wall anchors provide a strong and secure fixing in a wide range of board materials. They can be quickly installed using a screwdriver or a dedicated Hollow Wall Anchor Setting Tool. Once set, the screw can be removed without dislodging the anchor body, allowing for easy removal of the attached fixture—ideal for redecorating or repositioning.
Perfect for securing the Lupit plaster ceiling upper plate, these anchors—commonly referred to as drywall anchors or molly bolts—ensure optimal load distribution and a reliable hold in plasterboard.
Specifications:
- Thread size: M6
- Anchor length: 65 mm
- Hole diameter required: 13 mm
- Suitable for wall thickness: 14–32 mm
- Material: Zinc-plated steel
Features:
- Excellent load-bearing capacity
- Even load distribution
- Durable construction
4 pieces per set, supplied in a resealable plastic zip bag.